Curtis 1244 Manual, Rev. E
35
throttle map setting, as the throttle input increases and will reach maximum
output when the throttle input enters the upper deadband (crosses the throttle
max threshold).
Fig. 17 rottle maps for
controller with maximum
speed set at 80% and creep
speed set at 10%.
e rottle Map operates within the window established by the Creep
Speed, Max Speed, rottle Deadband, and rottle Max parameters, as shown
in Figure 18. Creep Speed and Max Speed define the controllers output range,
while rottle Deadband and rottle Max define the throttles active range.
ese four parameters, together with the rottle Map, determine the controllers
output response to throttle demand.
Fig. 18 Inuence of various
parameters on controller
output response to throttle
demand.
THROTTLE INPUT (percent of active range)
CONTROLLER OUTPUT (PWM percent)
80%
60%
50%
40%
30%
20%
THROTTLE MAP
100
90
80
70
60
50
40
30
20
10
0
100908070605040302010 0
SPEED PARAMETERS
10% Creep Speed
80% Max Speed
THROTTLE INPUT (percent)
CONTROLLER OUTPUT (PWM percent)
100908070605040302010 0
SPEED PARAMETERS
10% Creep Speed
80% Max Speed
THROTTLE
PARAMETERS
15% Deadband
90% Throttle Max
40% Throttle Map
80% Max Speed
40% Throttle Map
(38% output at half throttle)
10% Creep Speed
15% Throttle Deadband
90% Throttle Max
HALF THROTTLE
100
90
80
70
60
50
40
30
20
10
0
3 — PROGRAMMABLE PARAMETERS: Throttle Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis 1244 and is the answer not in the manual?

Curtis 1244 Specifications

General IconGeneral
BrandCurtis
Model1244
CategoryController
LanguageEnglish

Related product manuals