User Guide DDOC0199-000-A9
1-Slot Data Transport System (CSfC) 11 - 2 Remove / Replace
© 2024 Curtiss-Wright Defense Solutions Revision 0.0
11.1.2 Remove
CAUTION
EQUIPMENT DAMAGE. The RMC module is hot-swappable (remove / install with power applied),
however, extreme caution must be used to ensure all ESD handling precautions are followed.
Failure to properly handle the RMC module will result in equipment damage.
1. Rotate the door latch a quarter turn and open the door.
NOTE
Removal may also be requested with the CLI command rmcctl.
2. Press and hold the removal request button for three to five seconds to request removal of the
RMC module.
The STATUS LED will blink at 5Hz for two seconds to acknowledge the request. After
acknowledgment, the system will unmount and prepare the RMC module for removal.
When the RMC module is ready for removal, the STATUS LED will blink one time every
five seconds.
3. Grasp the RMC module handle and pull the unit straight out.