S0202040
Page 18
Specifications for Solar 200W-V
Return to Master Table of Contents
HYDRAULIC SYSTEM COMPONENT SPECIFICATIONS
Control Valve
Relief Valves (Main):
Left Side Spools:
(28 mm [1.10"] diameter)
Right Side Spools:
(28 mm [1.10"] diameter)
Overload Relief Pressure:
320.0 kg/sq cm (4,600 psi) – travel
320/350 kg/cm
2
(4,600/5,000 psi) – all other
Swing
Boom 2
Arm 1
Tr avel
Option
Bucket
Boom 1
Arm 2
360 kg/cm
2
(5,119 psi)
Boom, Arm, Bucket, Dozer/Outrigger
Remote Travel Control Valve
Ty pe :
Pressure/Stroke:
Pilot Control
30 kg/cm
2
(427 psi) at 30° pedal angle
Remote Implement Control Valve
Ty pe :
Pressure/Stroke:
Pilot Control
26.5 - 29.5 kg/cm
2
(377 - 420 psi) at 6.5 mm (0.256")
stroke
Pilot Accumulator
PilotNitrogen Charge:
Volume:
15 kg/cm
2
(213 psi)
350 cm
3
(19.5 in
3
)
Transmission Accumulator
Nitrogen Charge:
Volume:
8 kg/cm
2
(114 psi)
700 cm
3
(42.7 in3)
Brake Accumulator
Nitrogen Charge:
Volume:
30 kg/cm
2
(426 psi)
700 cm
3
(42.7 in
3
)