- 17 -
8.
CONNECTION PROCEDURE AND GROUND FOR SAFETY USE (continued)
8.1.2 STICK WELDING
The following figure shows the cable connections for stick welding with DC electrode positive
(welding stick positive, base metal negative). When using DC electrode negative, switch the
holder cable with the base metal cable.
1. Ground the base metal (if required by local laws or codes).
2. Connect the base metal cable to the negative
٤
- output terminal on the welding power
source.
3. Connect the holder to the positive
٤
+ output terminal on the welding power source.
8.2 Connecting of the Base Metal Cable and Stick Holder Cable
When connecting the base metal cable and stick holder cable to the welding power source,
attach the cable plug DIX SK 50 (supplied).
Base metal cable
38m m
2
or more)
Firmly attach the base metal cable to the base metal.
Base metal
Weld ing cable
Holder
Groove
Cable
Biss
Grip
Sleeve
Connector
Conductor
٤
+
٤
