User’s Manual
171
Alarm-out Port
Click
to display setting interface.
General Alarm: Enable general alarm and select the alarm output
port.
Ext. Alarm: Connect the alarm box to the Device and then enable
it.
Wireless Siren: Connect the wireless gateway to the Device and
then enable it. For details, see "5.12 IoT Function."
When an alarm event occurs, the system links the peripheral alarm
devices connected to the selected output port.
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300
seconds. If you enter 0, there will be no delay.
Show Message
Select the
check box to enable a pop-up alarm
message in your local host PC.
Report Alarm
Select the
check box to enable the system to upload the
alarm signal to the network (including alarm center) when an alarm
event occurs.
Not all models support this function.
The corresponding parameters in the alarm center should be
configured. For details, see "5.15.1.12 Configuring Alarm Center
Settings."
Send Email
Select the
check box to enable the system to send an
email notification when an alarm event occurs.
To use this function, make sure the email function is enabled in
Main
Menu > NETWORK > Email
.
Record Channel
Select the channel(s) that you want to record. The selected channel(s)
starts recording after an alarm event occurs.
The recording for intelligence event and auto recording function must
be enabled. For details, see "5.1.4.9 Configuring Recorded Video Storage
Schedule" and "5.9.1 Enabling Record Control."
PTZ Linkage
Click
to display the PTZ interface.
Enable PTZ linkage actions, such as selecting the preset that you want
to be called when an alarm event occurs.
To use this function, the PTZ operations must be configured. For details,
see "5.4 Controlling PTZ Cameras."
Post Record
Set a length of time for the Device to delay turning off recording after
the alarm is cancelled. The value ranges from 10 seconds to 300
seconds.