Set the parameters for the SIP server using the following information.
Parameter
Description
IP Addr. The IP address of the VTO which works as SIP server.
Port 5060
Username
Keep the default value.
Password
SIP Domain VDP
SIP Server Username
The user name and password for the web interface of the SIP
server.
SIP Server Password
Table 4-1: SIP Server Parameters
5.4.5 Configuring Call Number and Group Call
Configure the call number on every VTO, then each VTO device can call the defined room
when you press the call button. On the SIP server, enable the group call function, and when
calling a master VTH, the extension VTH devices receive the call as well.
Enabling or disabling group call function will erase all the added VTH, so you need to perform
this operation before adding VTO and VTH.
Select Local Setting > Basic.
In the Villa Call No. input box, enter the room number you need to call, and then click
Confirm to save. Repeat this operation on every villa VTO web interface.
Log in the web interface of the SIP server, and then select Local Setting > Basic.
Select the Group Call check box, and then click Confirm.
The VTO will reboot, and when calling a master VTH, the extension VTH devices receive
the call as well.

Other manuals for Dahua VTO Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua VTO Series and is the answer not in the manual?

Dahua VTO Series Specifications

General IconGeneral
CategoryIntercom System
DimensionsVaries by model
WeightVaries by model
ModelVTO Series (multiple models exist within the series)
Video Resolution1080p, 720p (depends on model)
AudioTwo-way audio communication
Network InterfaceEthernet (some models support Wi-Fi)
Power Supply12V DC or PoE (Power over Ethernet), Varies by model
Operating Temperature-30°C to +60°C (-22°F to +140°F)
WeatherproofIP65
Supported ProtocolsSIP