Configure the parameters, and be sure to add the SIP server.
Parameter
Description
Rec No.
The VTO number you configured for the target VTO. See the
details in "4.3.2 Configuring VTO Number."
Register Password Keep the default value.
Build No.
Available only when other servers work as SIP server.
Unit No.
IP Address The IP address of the target VTO.
Username
The user name and password for the web interface of the
target VTO
Password
Click Save.
5.5.1 Adding a Room Number
Add the planned room number to the SIP server and then configure the room number on VTH
devices to connect them to the network. This section applies to the condition in which a VTO
device works as SIP server, and if you use other servers as SIP server, see the corresponding
manual for the detailed configuration. Dial the VTH room number from the VTO unit.
The room number can contain 6 digits of numbers or letters or their combination at most, and
it cannot be the same as any VTO number.
Log in the web interface of the SIP server, and then select Household Setting > Room No.
Management.

Other manuals for Dahua VTO Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua VTO Series and is the answer not in the manual?

Dahua VTO Series Specifications

General IconGeneral
CategoryIntercom System
DimensionsVaries by model
WeightVaries by model
ModelVTO Series (multiple models exist within the series)
Video Resolution1080p, 720p (depends on model)
AudioTwo-way audio communication
Network InterfaceEthernet (some models support Wi-Fi)
Power Supply12V DC or PoE (Power over Ethernet), Varies by model
Operating Temperature-30°C to +60°C (-22°F to +140°F)
WeatherproofIP65
Supported ProtocolsSIP

Related product manuals