5 Application guidelines
Installer reference guide
13
ERGA04~08DAV3(A) + EHVH04+08S23DAV
Daikin Altherma – Low temperature split
4P499573-1 – 2017.12
Configuration
Setting Value
Unit temperature control:
#: [2.9]
Code: [C-07]
2 (Room thermostat): Unit
operation is decided based on
the ambient temperature of the
user interface.
Number of water temperature
zones:
#: [4.4]
Code: [7-02]
0 (Single zone): Main
Benefits
Easy. Same installation as for one room, but with thermostatic
valves.
Underfloor heating or radiators – Multiple external
room thermostats
Setup
M2
B C
A
a
b
a
M1
A Main leaving water temperature zone
B Room 1
C Room 2
a External room thermostat
b Bypass valve
For each room, a shut-off valve (field supplied) is installed to avoid
leaving water supply when there is no heating demand.
A bypass valve must be installed to make water recirculation
possible when all shut-off valves are closed. To guarantee reliable
operation, provide a minimum water flow as described in table "To
check the water volume and flow rate" in "6.4 Preparing water
piping"on page25.
The user interface connected on the indoor unit decides the space
operation mode. Mind that the operation mode on each room
thermostat must be set to match the indoor unit.
The room thermostats are connected to the shut-off valves, but do
NOT have to be connected to the indoor unit. The indoor unit will
supply leaving water all the time, with the possibility to program a
leaving water schedule.
Configuration
Setting Value
Unit temperature control:
#: [2.9]
Code: [C-07]
0 (Leaving water): Unit operation
is decided based on the leaving
water temperature.
Number of water temperature
zones:
#: [4.4]
Code: [7-02]
0 (Single zone): Main
Benefits
Compared with underfloor heating or radiators for one room:
Comfort. You can set the desired room temperature, including
schedules, for each room via the room thermostats.
Heatpump convectors - Multiple rooms
Setup
B
A
a a
C
A Main leaving water temperature zone
B Room 1
C Room 2
a Remote controller of the heatpump convectors
The desired room temperature is set via the remote controller of
the heatpump convectors.
The user interface connected on the indoor unit decides the space
operation mode.
The heating demand signals of each heat pump convector are
connected in parallel to the digital input on the indoor unit (X2M/1
and X2M/4). The indoor unit will only supply leaving water
temperature when there is an actual demand.
INFORMATION
To increase comfort and performance, Daikin recommends
to install the valve kit option EKVKHPC on each heatpump
convector.
Configuration
Setting Value
Unit temperature control:
#: [2.9]
Code: [C-07]
1 (External room thermostat):
Unit operation is decided by the
external thermostat.
Number of water temperature
zones:
#: [4.4]
Code: [7-02]
0 (Single zone): Main
Benefits
Compared with heatpump convectors for one room:
Comfort. You can set the desired room temperature, including
schedules, for each room via the remote controller of the
heatpump convectors.