8 Configuration
Installer reference guide
49
ERGA04~08DAV3(A) + EHVH04+08S23DAV
Daikin Altherma – Low temperature split
4P499573-1 – 2017.12
4 Turn the left dial to select the second part of the
setting
00
01 15
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
1
5 Turn the right dial to modify the value from 15 to 20.
00
01 20
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
1
6 Press the left dial to confirm the new setting.
7 Press the center button to go back to the home
screen.
INFORMATION
When you change the overview settings and you go back
to the home screen, the user interface will show a popup
screen and request to restart the system.
When confirmed, the system will restart and recent
changes will be applied.
8.2 Configuration wizard
After first power ON of the system, the user interface will guide you
using the configuration wizard. This way you can set the most
important initial settings. This way the unit will be able to run
properly. Afterwards, more detailed settings can be done via the
menu structure if required.
You can find a short overview of the settings in the configuration
here. All the settings can also be adjusted in the settings menu (use
the breadcrumbs).
For the setting… Refer to…
Language [7.1]
Time/date [7.2]
Hours
Minutes
Year
Month
Day
System
Indoor unit type (read only) "Backup heater"on page66
Backup heater type [9.3.1]
Domestic hot water [9.2.1]
Emergency [9.5]
Number of zones [4.4] "8.4.5Space heating"on
page58
Backup heater
Voltage [9.3.2] "Backup heater"on page66
Configuration [9.3.3]
Capacity step 1 [9.3.4]
Additional capacity step 2 [9.3.5]
(if applicable)
Main zone
For the setting… Refer to…
Emitter type [2.7] "8.4.3Main zone"on
page54
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Schedule [2.1]
Additional zone (only if [4.4]=1)
Emitter type [3.7] "8.4.4Additional zone"on
page57
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Schedule [3.1]
Tank
Heat up mode [5.6] "8.4.6Tank"on page61
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
8.3 Possible screens
8.3.1 Possible screens: Overview
The most common screens are as follows:
+
a
b
c
c2c1
a Home screen
b Main menu screen
c Lower level screens:
c1: Setpoint screen
c2: Detailed screen with values
8.3.2 Home screen
Press the
button to go back to the home screen. You see an
overview of the unit configuration and the room and setpoint
temperatures. Only symbols applicable for your configuration are
visible on the home screen.