4 About the units and options
Installer reference guide
9
ERGA04~08DAV3(A) + EHVH04+08S23DAV
Daikin Altherma – Low temperature split
4P499573-1 – 2017.12
4 About the units and options
4.1 Overview: About the units and
options
This chapter contains information about:
▪ Identifying the outdoor unit
▪ Identifying the indoor unit
▪ Combining outdoor and indoor units
▪ Combining the outdoor unit with options
▪ Combining the indoor unit with options
4.2 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1 Identification label: Outdoor unit
Location
Model identification
Example: ERGA06DAV3
Code Explanation
ER European split outdoor pair heat pump
G Medium water temperature – ambient zone: −10~
−20°C
A Refrigerant R32
06 Capacity class
DA Model series
V3 Power supply
4.2.2 Identification label: Indoor unit
Location
Model identification
Example: EHVH04S23DAVG
Code Description
E European model
HV Floor-standing indoor unit with integrated tank
H H=Heating only
04 Capacity class
S Integrated tank material: Stainless steel
Code Description
23 Integrated tank volume
DA Model series
V Model with single phase anti-legionella heater in
the domestic hot water tank. (Without backup
heater in the space heating circuit.)
G G=Grey model
[blank]=White model
4.3 Combining units and options
4.3.1 Possible options for the outdoor unit
Drain pan kit (EKDP008D)
The drain pan kit is required to gather the drain from the outdoor
unit. The drain pan kit consists of:
▪ Drain pan
▪ Installation brackets
For installation instructions, see the installation manual of the drain
pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain
pan.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the drain
pan heater.
U-beams (EKFT008D)
The U-beams are installation brackets on which the outdoor unit can
be installed.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the
outdoor unit.
4.3.2 Possible options for the indoor unit
User interface used as room thermostat (EKRUDAS)
▪ The user interface used as room thermostat can only be used in
combination with the user interface connected to the indoor unit.
▪ The user interface used as room thermostat needs to be installed
in the room that you want to control.
For installation instructions, see the installation and operation
manual of the user interface used as room thermostat.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Digital I/O PCB (EKRP1HB)
The digital I/O PCB is required to provide following signals:
▪ Alarm output
▪ Space heating/cooling On/OFF output
Final English - Tanslations in progress