7 Installation
Installer reference guide
30
ERGA04~08DAV3(A) + EHVH04+08S23DAV
Daikin Altherma – Low temperature split
4P499573-1 – 2017.12
7.2 Opening the units
7.2.1 About opening the units
At certain times, you have to open the unit. Example:
When connecting the refrigerant piping
When connecting the electrical wiring
When maintaining or servicing the unit
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover
is removed.
7.2.2 To open the outdoor unit
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING
See "7.5.8 To connect the refrigerant piping to the outdoor unit"on
page 36 and "7.9.6 To connect the electrical wiring on the outdoor
unit"on page42.
7.2.3 To open the indoor unit
1 Remove the top panel.
T25
2 Remove the user interface panel. Open the hinges at the top
and slide the top panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the panel to prevent damage.
2
1
1
3
3 If necessary, remove the front plate. This is, for example,
necessary in the following cases:
"7.2.5 To lower the switch box on the indoor unit" on
page31
"7.8.5To connect the drain hose to the drain"on page40
When you need access to the high voltage switch box
T25
7.2.4 To open the switch box cover of the
indoor unit
T25