10 | Configuration
Installer reference guide
145
ERGA04~08E + EHVH04+08SU18+23E
Daikin Altherma 3 R F
4P629090-1C – 2022.08
Item Description
h Indoor unit / domestic hot water tank
h1 Floor-standing indoor unit with integrated tank
Wall-mounted indoor unit
Wall-mounted indoor unit with separated tank
h2 Water pressure
i Main zone
i1 Installed room thermostat type:
Unit operation is decided based on the ambient temperature
of the dedicated Human Comfort Interface (BRC1HHDA used
as room thermostat).
Unit operation is decided by the external room thermostat
(wired or wireless).
No room thermostat installed or set. Unit operation is
decided based on the leaving water temperature regardless
of the actual room temperature and/or heating demand of
the room.
i2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
i3
21
Measured room temperature
(a)
i4
35
Leaving water temperature setpoint
(a)
j Holiday mode
Holiday mode active
k Additional zone
k1 Installed room thermostat type:
Unit operation is decided by the external room thermostat
(wired or wireless).
No room thermostat installed or set. Unit operation is
decided based on the leaving water temperature regardless
of the actual room temperature and/or heating demand of
the room.
k2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
k3
45
Leaving water temperature setpoint
(a)