6 | Application guidelines
Installer reference guide
50
ERGA04~08E + EHVH04+08SU18+23E
Daikin Altherma 3 R F
4P629090-1C – 2022.08
6.4.3 Setup and configuration – DHW tank
For large DHW consumptions, you can heat up the DHW tank several times
during the day.
To heat up the DHW tank to the desired DHW tank temperature, you can use the
following energy sources:
- Thermodynamic cycle of the heatpump
- Electrical backup heater
For more information about optimizing the energy consumption for producing
domestic hot water, see "10Configuration"[4138].
6.4.4 DHW pump for instant hot water
Setup
a
b
c
d
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Recirculation connection
By connecting a DHW pump, instant hot water can be available at the tap.
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see "9.3.5To connect the domestic hot water
pump"[4126].
For more information about connecting the recirculation connection, see
"8.6.5To connect the recirculation piping"[4109].
Configuration
For more information, see "10Configuration"[4138].
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.