EasyManua.ls Logo

Daikin Altherma ERGA04E V3 Series - Special Requirements for R32 Units

Daikin Altherma ERGA04E V3 Series
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 | Unit installation
Installer reference guide
65
ERGA04~08E + EHVH04+08SU18+23E
Daikin Altherma 3 R F
4P629090-1C – 2022.08
Mind the following spacing installation guidelines:
300
≥650
500
(mm)
100
Additionally to the spacing guidelines: The room where you install the indoor unit
must also comply with the conditions described in "7.1.5 Installation
patterns"[466].
INFORMATION
If you have limited installation space, do the following before installing the unit in its
final position: "7.4.4 To connect the drain hose to the drain" [4 82]. It requires to
remove one or both side panels.
The foundation must be strong enough to bear the weight of the unit. Take the
weight of the unit with a domestic hot water tank full of water into account.
Make sure, in the event of a water leak, water cannot cause any damage to the
installation space and surroundings.
Do NOT install the unit in places such as:
In places where a mineral oil mist, spray or vapour may be present in the
atmosphere. Plastic parts may deteriorate and fall off or cause water leakage.
Sound sensitive areas (e.g. near a bedroom), so that the operation noise will
cause no trouble.
In places with high humidity (max. RH=85%), for example a bathroom.
In places where frost is possible. Ambient temperature around the indoor unit
must be >5°C.
7.1.4 Special requirements for R32 units
Additionally to the spacing guidelines: The room where you install the indoor unit
must also comply with the conditions described in "7.1.5 Installation
patterns"[466].
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use means to accelerate the defrosting process or to clean the
equipment, other than those recommended by the manufacturer.
Be aware that R32 refrigerant does NOT contain an odour.
WARNING
The appliance shall be stored so as to prevent mechanical damage and in a well-
ventilated room without continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric heater) and have a room
size as specified below.