10 | Configuration
Installer reference guide
203
ERGA04~08E + EHVH04+08SU18+23E
Daikin Altherma 3 R F
4P629090-1C – 2022.08
Possible outcomes when quiet mode is set to Automatic
If... Then quiet mode =...
Restrictions
enabled?
Restrictions
(time + level)
defined?
Schedule
programmed?
No N/A No OFF
Yes Follows schedule
Yes No No OFF
Yes Follows schedule
Yes No Follows restriction
Yes During restricted time: If
restricted level is stricter than
scheduled level, then follows
restriction. Else, follows
schedule.
Outside restricted time:
Follows schedule.
Electricity prices and gas price
Only applicable in combination with the bivalent function. See also
"Bivalent"[4221].
# Code Description
[7.5.1] N/A Electricity price > High
[7.5.2] N/A Electricity price > Medium
[7.5.3] N/A Electricity price > Low
[7.6] N/A Gas price
INFORMATION
Electricity price can only be set when bivalent is ON ([9.C.1] or [C-02]). These values
can only be set in menu structure [7.5.1], [7.5.2] and [7.5.3]. Do NOT use overview
settings.
To set the gas price
1 Go to [7.6]: User settings > Gas price.
2 Select the correct gas price.
3 Confirm the changes.
INFORMATION
Price value ranging from 0.00~990valuta/kWh (with 2 significant values).
To set the electricity price
1 Go to [7.5.1]/[7.5.2]/[7.5.3]: User settings > Electricity
price > High/Medium/Low.
2 Select the correct electricity price.
3 Confirm the changes.