EasyManua.ls Logo

Daikin Altherma ERGA04E V3 Series - Page 275

Daikin Altherma ERGA04E V3 Series
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 | Technical data
Installer reference guide
275
ERGA04~08E + EHVH04+08SU18+23E
Daikin Altherma 3 R F
4P629090-1C – 2022.08
Electrical connection diagram
For more details, please check the unit wiring.
4 core
2×0.75
230 V
1
1
X2M: 5-6
X5M: 9-10
A8P: X801M: 1-5
A8P: X801M: 2-5
A8P: X801M: 3-5
A8P: X801M: 4-5
A4P: Y1-YC
X2M: 7-9
A4P: X1-X2
X2M: 1-2
X5M: 5-6
X5M: 3-4
A4P: Y2-YC
X2M: 7-9
230 V
230 V
230 V
230 V
4D130331D
A11P: X5: 4-5
A11P: X9: 1-2-3
(F1B)
5
6
5
5
6
2×0.75
3
3
X5M: 14
X5M: 13-14
X5M: 13
2
2
2
X10M: 1-2
2×0.75
X10M: 3-4
2×0.75
X5M: 11-12
X5M: 7-8
4
4
4
2×0.75
A15P: X1M: H-C-com
X2M: L-N
A2P: X1M: 1-3
A2P: X1M: C-com-H
A3P
2×0.75
7
A2P: X1M: 1-2
7
- In case of signal cable: keep minimum distance to power cables >5 cm
Notes:
2-way valve
signal
2 core
signal
2 core
signal
2 core
signal
2 core
Power limitation demand input 4
Power limitation demand input 3
Power limitation demand input 2
Power limitation demand input 1
FIELD SUPPLY
OPTIONAL PART
Only for *KRP1AHTA
Only for *KRP1HB*
FIELD SUPPLY
INDOOR UNIT
Cooling/heating ON/OFF output
Circulation pump for domestic hot water
M2S for cooling mode
Ext. heat source (e.g. boiler)
Alarm indication
signal
2 core
2 core
2 core
2 core
2 core
Cooling/heating
ON/OFF output
NO valve: X2M: 21-28
NC valve: X2M: 21-29
Changeover to
ext. heat source output
Alarm output
3 core
3 core
3 core
2 core
signal
2 core
Normal kWh rate power supply for indoor unit:
Preferential kWh rate power supply contact
Unit preferential kWh rate power supply:
230 V + earth
Only for preferential kWh rate power supply installation
Unit power supply:
230 V + earth
Only for normal power supply installation
OUTDOOR UNIT
STANDARD PART
POWER SUPPLY
WLAN module
communication
5 core
A20P: J2
X6M: L1-L2-L3 + earth
or L-N + earth
or L1-L2-L3-N + earth
5 or 4 or 3 core
Backup heater power supply (3/6/9 kW):
400 V or 230 V + earth
Electricity meter pulse input 1
Smart Grid contact K2A
Electricity meter pulse input 2
Smart Grid pulse meter
signal
2 core
signal
2 core
Only for high voltage Smart Grid
Smart Grid contact S11S
Only for low voltage Smart Grid
FIELD SUPPLY
FIELD SUPPLY
2 core
Safety thermostat Q4L
Only for high voltage Smart Grid
Only for low voltage Smart Grid
Smart Grid contact K1A
2 core
Smart Grid relay K1A
2 core
Smart Grid relay K2A
OPTIONAL PART
Smart Grid contact S10S
High voltage Smart Grid control supply: 230 V
X1M: 1-2-3
X1M: 1-2-3
X1M: L-N-earth
Only for KRCS01-1 or EKRSCA1
External thermistor (indoor or outdoor)
signal
2 core
R2T External sensor (floor or
ambient)
Only for *KRTETS
signal
2 core
(3m included)
A14P: P1-P2 user interface
Only for
Human Comfort Interface
Only for LAN adapter
Only for *KRTR* (wireless room thermostat)
Only for EKRTR1
Only for EKRTRB
Only for *KRTW* (wired room thermostat)
5 core for C/H operation
4 core for H only operation
3 core for C/H operation
2 core for H only operation
communication
2 core
OPTIONAL PART
External room thermostat / Heat pump convector
(main and/or additional zone)
main: X2M: 30-31-34-35
add: X2M: 30-31-34a-35a
main: X2M: 30-34-35
add: X2M: 30-34a-35a
signal
signal
Only for heat pump convector
main: X2M: 30-35
add: X2M: 30-35a
main & add: X2M: 3-4
signal
4 core
A13P: P1-P2 LAN adapter
2 core
communication

Table of Contents

Related product manuals