Si04-756 Removal of Connecting Duct
Removal Procedure 31
9. Removal of Connecting Duct
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1
Detach the humidifying
hose from the duct unit.
Preparation
Remove the front grille
according to "Removal of
Front Grille".
Since inside of the
humidifying hose has
ridges, move the hose up
and down to remove.
2
Remove the screw of
the duct unit.
3
Lift the right side to
unfasten the
projections and slide
the duct unit to the left.
Move alternately.
(R13968)
Humidifying
hose
(R5721)
Duct unit
Projection
(R18710)