SiUS04-924_A Troubleshooting
102 Service Diagnosis
Troubleshooting
Check No.17
Refer to P.117
Check No.19
Refer to P.118
Note: Refer to “Application of silicon grease to a power transistor and a diode bridge” on page 188 for
detail.
(R14445)
Caution
NO
Slightly dirty
NG
Too dirty
OK
NO
YES
NO
YES
YES
Turn off the power and turn it on
again to start the system.
Check the radiation fin
temperature.
Above A?
Check No. 17
Check the installation condition.
Check if the silicon grease
applied properly on the
radiation fin. If not, apply it
(
). (See Note.)
Replace the outdoor unit
PCB.
Replace the fan motor.
Correct the connectors and
fan motor leads.
Replace the outdoor unit
PCB.
Clean up the radiation fin.
Silicon grease
Part No.: 1
172698
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Error displayed again?
Has PCB been replaced?
Check No. 19
Check the outdoor fan or
related.
Radiation fin dirty?
A 105°C (221°F)