Outdoor Unit SiUS04-924_A
Removal Procedure 173
2.4 Removal of Fan Motor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1 Cut the clamps at 2
locations.
2
3
Remove the 2 lower
screws first.
Then, remove the 2
upper screws.
Be sure to remove the lower
screws first. If the upper screws
are removed first, the fan motor,
the center of gravity of which is
toward the front, may tilt down
or fall, causing injury.
4 Remove the fan motor. When reassembling, be sure to
place the wire harness lower.
(R9630)
(R6442)
2
1
(R6443)
Fan motor
(R6444)
Harness