EasyManuals Logo
Home>Daikin>Air Conditioner>FTYN35DV3B ATY35DV2

Daikin FTYN35DV3B ATY35DV2 User Manual

Daikin FTYN35DV3B ATY35DV2
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
SiBE01-503 Troubleshooting
Service Diagnosis 57
4. Troubleshooting
4.1 Error Codes and Description
: Displayed only when system-down occurs.
Code Description
Reference
Page
System
00
Normal
Indoor
Unit
A1
Indoor unit PCB abnormality 58
A5
Freeze-up protection control or high pressure control 59
A6
Fan motor or related abnormality (AC motor) 61
C4
Heat exchanger thermistor abnormality 62
C9
Room temperature thermistor abnormality 62
Outdoor
Unit
F6
High pressure control in cooling 63
J6
Heat exchanger thermistor or related abnormality 65

Table of Contents