Page #41 background imageLoading...
Page #41 background image
Operation Manual SiBE81-909
40 Humidifying Air Purifier
31
Care & Cleaning
6
Restore the deodorizing catalyst unit.
9
10
11
Restore the front panel.
Plug the power supply cord in.
Press and hold the air-purifying
filter reset button at the top of the
unit for 2 seconds.
(A double acoustic tone is emitted
and the Air-purifying filter lamp goes
out.)
• After replacing the pleated filter, the
Air-purifying filter lamp does not go
out unless the filter reset button is
pressed and held for 2 seconds.
• Holding the deodorizing catalyst unit by the handle,
fit the projections on the unit into the grooves (4
locations) at the bottom of the main unit and press
the deodorizing catalyst unit into the main unit.
7
Restore the UNIT1.
• Holding UNIT1 by the handle, fit the projections on
the unit into the grooves (2 locations) at the bottom
of the main unit, and press UNIT1 into the main unit.
8
Restore the water tank.
• For replacement pleated filters, contact the service shop. (See the ATTENTION on page 38.)
• The pleated filter does not need replacing until the Air-purifying filter lamp lights or flashes.
Replace the pleated filter if the Air-purifying filter lamp lights or flashes, even if the filter is not dirty. Visible
grime and filter performance are not proportional to one another.
• The replacement interval for the pleated filter varies according to how the unit is used and where it is located.
The Air-purifying filter lamp lights after about 1 year in a home where every day 10 cigarettes are smoked
and the unit is used.
(The replacement interval shortens when the unit is used where the air is particularly dirty.)
• Dispose of used pleated filters as noncombustible waste. (Material: polypropylene/polyester nonwoven
textile)
• If you replace the pleated filter before the Air-purifying filter lamp lights because dirt bothered you, press
and hold the pleated filter reset button for 2 seconds.
XPage 29.
HUM
RESET
(Push for 2 sec.)
RESET
(Push for 2 sec.)
(1)
Fit here.
Deodorizing catalyst unit
(2) Press inward until
hearing clicking sound.
(1)
Fit here.
UNIT1
(2) Press inward until
hearing clicking sound.
XPage 29.
Pleated filter replacement

Other manuals for Daikin MCK75JVM-K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin MCK75JVM-K and is the answer not in the manual?

Daikin MCK75JVM-K Specifications

General IconGeneral
BrandDaikin
ModelMCK75JVM-K
CategoryAir Cleaner
LanguageEnglish