MANUALE INSTALLATORE RELEASE 00.1 PAG. 9
Push to highlight the set value, then use or to
change it, push again to confirm it and then to go back to
previous menu.
5-1-2 Boiler Delta T
This value can be changed only after consulting the manufacturer
(default setting: 2°C).
Push to go back to previous menu.
5-2 Group temperatures set up
Push to access this menu. The display will show:
5-2-1 Group 1 temperature set up
Push to access this menu and change GROUP 1 temperature set
up (default setting: 95C°).
Push again to highlight the pre-set value, then use or to change
it, push again to confirm it and then to go back to previous menu.
Follow the same instructions to change the temperatures of all the other machine
groups (5-2-2, 5-2-3, 5-2-4).
5-3 Group extra set
Do not change this value to avoid jeopardizing group stability
(default setting: 2°C).
5-4 MCS steam temperature set up
Push to access this menu and change the temperature limit the
MCS must not exceed (default setting: 55C°).