75 Piranha2 User’s Manual
Code Command Short
Form
Parameters Description
Parameters:
i = integer
f = float
t = tap selector
s = string
x1 = pixel start
number
x2= pixel end number
[]= optional
parameter
start and end values in a range
from 1 to sensor pixel count.
13 get_prnu_coeff
gpc i
Read the PRNU coefficient.
16 get_processing_status
gps
Read the status of last
executed command and coded
value for all pending
monitoring task warnings.
17 get_sensor_serial
gss
Read the sensor serial number.
18 help
h
Display the online help.
19 region_of_interest
roi i i
Set the pixel range for reading
end-of-line statistic and for the
region of pixels used in the
cag, cao, gl, gla, ccf, and
ccp commands. Pixel start and
end values in a range from 1 to
sensor pixel count.
20 reset_camera
rc
Reset the entire camera
(reboot).
21 reset_pixel_coeffs
rpc
Reset the pixel coefficients to
0.
22 restore_factory_settings
rfs
Restore the camera’s factory
settings. FPN and PRNU
coefficients reset to 0.
23 restore_user_settings
rus
Restore the camera's last saved
user settings and FPN and
PRNU coefficients.
24 set_analog_offset
sao t i
Set the analog offset. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter controls the digital
analog convertor (DAC), in a
range from 0 to 1023, that sets
analog offset. Offset increases
with higher values.
25 set_baud_rate
sbr i
Set speed of serial
communication port. Baud
rates: 9600, 19200, 57600, and
115200. Default baud: 9600
26 set_camera_id
sci s [s]
Set camera ID. The first
parameter is a character A to
Z, or 0 to 9. The second
optional parameter is the serial
number of the addressed
camera.
03-32-00493-11 DALSA

Table of Contents

Related product manuals