EasyManua.ls Logo

Dalsa P-2 Series - Page 76

Dalsa P-2 Series
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76 Piranha2 User’s Manual
Code Command Short
Form
Parameters Description
Parameters:
i = integer
f = float
t = tap selector
s = string
x1 = pixel start
number
x2= pixel end number
[]= optional
parameter
27 set_data_mode
sdm i
Set the data mode of camera
output to:
0: 8-bit, A/B/C/D ports, single
processor
1: 10-bit, A/B/C and D/E/F
ports, single processor
2: 8-bit, A/B and D/E ports,
dual processor
3: 10-bit, A/B/C and D/E/F
ports, dual processor
28 set_digital_offset
sdo t i
Subtracts the input value from
the video signal prior to the
PRNU correction. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter is the offset in a
range from 0 to 511. Use in
calibrated mode only.
29 set_exposure_mode
sem i
Set the exposure mode:
1: Internal SYNC and PRIN,
max line rate and exposure
time, factory setting
2: Internal SYNC and PRIN,
programmable line rate and
exposure time using
commands ssf and set
3: External SYNC, internal
PRIN, maximum exposure
time
4: Smart EXSYNC
5: External SYNC and PRIN
6: External SYNC, internal
PRIN, programmable
exposure time
30 set_exposure_time
set f
Set the exposure time in
exposure mode 2 or 6. Value
will be a floating point number
in µsecs
31 set_fpn_coeff
sfc i i
Set the FPN coefficient. The
first parameter is the pixel
number within the range 1 to
8192. The second value is a
specified value within the
range 0 to 127.
32 set_gain
sg t f
Set the analog gain. The first
parameter is the tap selection 1
to 4, 0 for all taps. The second
parameter is a gain value
specified from –10 to 10. A
03-32-00493-11 DALSA

Table of Contents