Spyder3 GigE Vision User’s Manual
DALSA 03-032-20027-02
41
Mode 7: Internally Programmable Line Rate, Maximum Exposure Time
In this mode, the line rate is set internally with a maximum exposure time.
Figure 20: Mode 7 Camera Timing
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this mode, the exposure time is set internally with a maximum line rate.
Figure 21: Mode 8 Timing
Programmable Perio
d
Frame Period
Readout
CR
Exposure Time
CR=Charge Reset
Frame Period
Programmable Period
CR Exposure Time
Readout
Exposure Time
Readout
Internal Sync set
with Command
ssf
Line Period
Exposure Time
Readout
Line Period
EXSYNC Falling
Edge ignored
during readout
EXSYNC Falling
Edge ignored
during readout