Settings:
Name Default Max value Min value Step Unit
ECO mode OFF ON OFF 1
ECO speed BD350GH 2500 4000 2500 1 rpm
ECO temperature 25 40 -40 0.1 Celsius (°C)
Automatic
ECO temperature
1 1 0 1
0=OFF
1=ON
4.2.7 ECO function
Operation in ECO mode reduces energy consumption and noise by controlling compressor speed as a
function of temperature. ECO mode can be selected only when using an NTC temperature sensor.
InECOmode,
• whenoperatingbelowECOtemperature,compressorsrunatthesetECOspeed,andtheStart
speedsettingwillbeoverruled,ifitdiersfromECOspeed.
• whenoperatingaboveECOtemperature,thecompressorsrunatRequestedspeed.