VLT
®
MICRO
No. Parameter Function Parameter Factory
Name Explanation Value Setting
78 PLC PLC (programmable d00:Disable PLC performing d00
Operation logic controller) d01:Execute cycle of PLC program
Mode operation mode d02:Continuously execute cycles
d03:Execute cycle step-by-step
d04:Continuously execute program
cycles step-by-step
79 PLC Fwd/Rev PLC fwd/rev d00 - d127 d00
Control control
80 Manufacturer Information d00:220V 1Ø/3Ø, 0.5 Hp d##
d02:220V 1Ø/3Ø, 1.0 Hp
d04:220V 1Ø/3Ø, 2.0 Hp
81 PLC Program Timing for step 1 d0.0 - d650 d0.0
82 Step Time Timing for step 2 d0.0 - d650 d0.0
83 Intervals Timing for step 3 d0.0 - d650 d0.0
84 Timing for step 4 d0.0 - d650 d0.0
85 Timing for step 5 d0.0 - d650 d0.0
86 Timing for step 6 d0.0 - d650 d0.0
87 Timing for step 7 d0.0 - d650 d0.0
88-94 Serial Communication (See Appendix D)
95 Auto Energy- Auto Energy-saving d00:Without energy-saving operation d00
saving d01:With energy-saving operation
96 Count Down Count down value d00 ~ d999 d00
Completion setting
97 Preset Count Preset count-down d00 ~ d999 d00
Down Compl.
98-99 Reserved
100 Software version Read only d1.06
101 Auto Accel/ Auto acceleration/ d00:Linear accel., decel. d00
Decel deceleration d01:Auto accel., linear decel.
Adjustment adjustment select d02:Linear accel., auto decel.
d03: Auto accel./decel.
102 Auto Voltage Auto voltage d00:Enable auto voltage reg. d03
Regulation regulation d01:Disable auto voltage reg.
d02:Disable auto volt reg. w/stop
d03:Disable auto volt reg. w/decel
103-110 Reserved
111 Decel S-curve d00 ~ d7 d00
Setting
112 Ext. Term d00 ~ d20 d00
Scanning time
Setting