T
c
Rated coolant liquid input temperature °C
Mounting Allowed mounting position according to IEC60034-7
Mass Mass of the electric machine kg
Duty Dened rotating electric machine duty cycles by IEC60034-1 standard
T
amb
Rated ambient temperature °C
IP rating Enclosure class according to IEC60034-5
Cooling Cooling method according to IEC60034-6
Rotation Direction of rotor
rotation with default phase order. Observed facing the D-end.
Max n Maximum rotation speed rpm
Insul. class Temperature rating (class) of insulation of the machine according to IEC60034-1
Temp. class
Temperature rating (class) of individual insulation materials of the insulation according
to IEC60034-1
Bear. / D-
end
Bearing type in the D-end of the machine
Bear. / N-
end
Bearing type in the N-end of the machine
Max.
pressure
Cooling liquid max pressure
Tightening torques
Tightening torque tolerances are: -10%...0% of the specied tightening torque. Exceeding the specied tightening torque
is not allowed.
Tightening torques to use unless otherwise noted
8.8 10.9 12.9
Thread Nm Nm Nm
M5 7 10 11
M6 11 17 19
M8 27 40 47
M10 54 79 93
M12 93 137 160
M14 148 218 255
M16 230 338 395
EM-PME375