Transportation
Heavy equipment. Handle with care during transportation
.
Electric machine
is
shipped in rst class condition. It has
been inspected and packed correctly
to
prevent damage from ordinary handling during shipment. During transportation, shocks, fails and
humidity should be avoided. Protect
the cooling holes for transportation.
The weight of the electric machine can be found on the machine rating plate, and in the product
data sheet.
Receiving and unpacking
Do not touch the electric machine during the insulation resistance check
.
Discharge the electric machine afterwards.
Check upon arrival and unpacking
The electric machine and the package must be inspected immediately upon arrival. Make
sure
that the rating plate data in the cover letter complies
with the purchase order. Any
external damage (in rotor, anges, electrical interfaces
and paint) must be photographed and
reported immediately.
It is recommended to measure
the insulation resistance of the machine upon arrival, or before
installing the electric machine.
Reference value of
150 M
Ω
shall be exceeded in room
temperature, otherwise contact Danfoss representative.
Lifting
Use correct, adequately dimensioned lifting devices and inspect them
before lifting.
Do not apply any excess weight on the electric machine when lifting.
Use correct lifting slings. Use correct position and angle of lifting. Permissible range of lifting angles is from 0° to 30º.
See the electric machine rating plate and data sheets for weight information.
Lift the electric machine using the correct lifting lugs/eyes only.
Do not go under a lifted load.