PVEO schematic and characteristic
kwa1464035903701
W
Warning
The PVEO is designed to have U
DC
=12 V or U
DC
=24 V.
The solenoids might be activated by voltage down to 6 V.
PVE-EX: PVE hysteresis
The controllability of the PVE depends on the solenoid valve bridge and the electronic capacity of the
module. Hysteresis is a measurement on spool position precision and repeatability. Hysteresis is not a
description of position maintaining.
PVES (left) and PVEH (right) position diagrams
kwa1464034339820
The PVES has an ASIC closed loop circuit and NC-S solenoids.
The PVEH has an ASIC closed loop circuit and NC solenoids.
Technical Information
Electrohydraulic Actuators PVE-EX
PVE-EX control
©
Danfoss | October 2017 BC00000393en-US0102 | 11