Fluid specification
The following data is from typical test results. Mineral based hydraulic oil with a viscosity of 21 mm
2
/s
[102 SUS] and a temperature of 50 °C [122 °F] was used for the hydraulic system testing.
Warning
The PVE is designed for use with pilot oil supply. Use without oil supply can harm the system.
Intermission is no longer than 5 seconds and not more than once per minute.
Oil consumption
Supply voltage Pilot oil flow per
PVE-EX Function
PVEO Versions PVEH Versions PVES Versions
l/min l/min l/min
Without Neutral 0 0 0
With Locked 0.1 0.1 0.1
Actuating 0.7 0.7 0.8
Oil viscosity, Oil temperature and Pilot pressure
Parameter Minimum Maximum Range
Oil viscosity
4 mm
2
/s
[39 SUS]
460 mm
2
/s
[2128 SUS]
12 - 75 mm
2
/s
[65 - 347 SUS]
Oil temperature
-30 ˚C
[-22 ˚F]
90 ˚C
[194 ˚F]
30 to 60 ˚C
[86 to140 ˚F]
Pilot pressure (relative to T pressure)
10 bar
[145 psi]
15 bar
[217 psi]
Nominal 13.5 bar
[196 psi]
Intermittent pressure peaks up to
– 50 bar [725 psi] –
Filtering in the hydraulic system
Required operating cleanliness level (ISO 4406, 1999 version)
18/16/13
PVE-EX electrical data
Specification PVEO Versions PVEH and PVES Versions
Grade of enclosure EN 60529 IP 66 and IP 69k
Ambient temperature Minimum -40 °C [-40 °F]
Maximum 60 °C [140 °F]
Maximum (submitting) surface temperature, T5 100 °C [212 °F]
Supply voltage Rated 12 / 24 V
DC
11-30 V
DC
Range PVEx-EX-12V 11-16 V
DC
N/A
Range PVEx-EX-24V 22-30 V
DC
N/A
Maximum ripple 5% 5%
Current consumption at
rated voltage (12/24 V
DC
)
Typical 0.74 A / 0.37 A 0.57 A / 0.33 A
Minimum 0.55 A / 0.29 A N/A
Maximum 0.82 A / 0.42 A N/A
Power consumption at rated voltage 9 W 7 W
Current via DI 0.1 A 0.1 A
Input impedance in relation 0.5 x U
DC
N/A 12 kΩ
Fault monitoring Maximum load N/A 60 mA
Reaction time at fault N/A 500 ms
For more information about PVEO, PVES and PVEH versions please refer to Nameplate description.
Technical Information
Electrohydraulic Actuators PVE-EX
Technical data
14 |
©
Danfoss | October 2017 BC00000393en-US0102