EasyManuals Logo

Danfoss PVE 7 Series User Manual

Danfoss PVE 7 Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
PVE-EX Dimensions
PVE-EX dimensions, mm [in]
Mounting of PVE-EX
1. Protect the LVDT pin (PVEH-EX and PVES-EX modules)
2. Ensure all O-rings are mounted and properly aligned in the grooves before mounting the PVE-EX to
the PVG valve.
3. The four screws (M6x40 mm) must be tightened to 9 ± 2 N•m [6.63 ± 1.48 lbt•ft]
V310 461
9 ±2N•m
4
W
Warning
The installation must be performed as intended in order to have a safe system and a proper functional
application. In a case of damage to enclosure, plug or cable, the PVE-EX module must be replaced. Please
refer to the information in this manual for an assistance, or consult with a professional.
Technical Information
Electrohydraulic Actuators PVE-EX
Installation
16 |
©
Danfoss | October 2017 BC00000393en-US0102

Table of Contents