Reaction times
Reaction time for PVES/PVEH versions
Supply voltage Function Minimum Rated Maximum
Disconnected by means of neutral switch From neutral position to max. spool travel 120 ms 150 ms 230 ms
From max. spool travel to neutral position 65 ms 90 ms 175 ms
Constant voltage From neutral position to max. spool travel 50 ms 120 ms 200 ms
From max. spool travel to neutral position 65 ms 90 ms 100 ms
Reaction time for PVEO versions
Supply voltage Function Minimum Rated Maximum
Power on From neutral position to max. spool travel
120 ms 180 ms 235 ms
Power off From max. spool travel to neutral position
Adjustment/calibration
The PVE-EX is pre-calibrated from the factory to be inside the dead band of the proportional valve. The
position sensor built into the PVE-EX cannot be adjusted by user. Any biasing of the position has to be
incorporated in the demand signal.
Technical Information
Electrohydraulic Actuators PVE-EX
Technical data
©
Danfoss | October 2017 BC00000393en-US0102 | 15