EasyManua.ls Logo

Danfoss PVE Series 4 - Direction Indication Feedback (-DI)

Danfoss PVE Series 4
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spool position feedback (-SP)
Spool travelSpool travel
0.5V
7 mm
100%
B port
7 mm
100%
A port
0 mm
Neutral
2.5V
4.5V
Usp
Us
Us
Us
Usp
Usp
25% U
DC
50% U
DC
75% U
DC
Direction indication feedback (-DI)
PVE with build in indication for spool movement direction are available.
The PVE–DI has dual power supply. U
DC1
only supplies solenoid valves. U
DC2
supplies electronics and feed
back. The PVE does not work without U
DC2
. DI-A and DI-B are relative standard mounting. The input
signal fault monitoring is disabled if U
DC1
is disabled. DI-A and DI-B are relative standard mounting.
The DI has two direction feeedback signals with output high (close to U
DC
) when the spool is in neutral
position. If the spool moves out of neutral position, the direction signal switches to low (< 0.2 V). One of
the signals goes low by spool ~0,8 mm out of neutral and high by spool within 0,4 mm out of neutral.
Both direction indication signals go low when the error indicator goes high.
Direction indication feedback
DI-A low
DI-B high
DI-A high
DI-B low
Spool position ‘x
mm [in]
B-port
PVBS away from PVE
A-port
PVBS towards PVE
0.4 0.8-0.8 -0.4 0
As shown in the figure, both “DI-A” and “DI-B” signals are “High” when the spool is in neutral position.
When the spool is moving in the A direction, the “DI-A” signal goes “Low” and the “DI-B” signal stays
“High”. The reverse is true when the spool is moved in the B direction.
Values for both Direction Indicators, pin A and pin B
Transition to low from high 0.8 ± 1 mm [0.031 in]
Transition to high from low 0.4 ± 1 mm [0.015 in]
Transition to low both pins error pin goes high
Maximum load of “DI-A” , “DI-B” 50 mA
Voltage DI high by load 20 mA > U
DC
– 1.5 V
Voltage DI high by load 50 mA > U
DC
– 2.0 V
Voltage DI low < 0.2 V
Technical Information PVE, Series 4 for PVG 32/100/120 and PVHC
Safety and monitoring
520L0553 • Rev GD • Jan 2014 17

Table of Contents

Related product manuals