VLT
®
6000 HVAC
169MG.60.B1.02 - VLT is a registered Danfoss trade mark
All about
VLT 6000 HVAC
Data
type
â– â– 
â– â– 
â–  Factory settings
Conversion
index
PNU Parameter Factory setting Range Changes 4-Setup
# description during operation
001
LanguageLanguage
LanguageLanguage
Language English Yes No 0 5
002
Active SetupActive Setup
Active SetupActive Setup
Active Setup Setup 1 Yes No 0 5
003
Copying of SetupsCopying of Setups
Copying of SetupsCopying of Setups
Copying of Setups No copying No No 0 5
004
LCP copyLCP copy
LCP copyLCP copy
LCP copy No copying No No 0 5
005
Max value of user-defined readoutMax value of user-defined readout
Max value of user-defined readoutMax value of user-defined readout
Max value of user-defined readout 100.00 0 - 999.999,99 Yes Yes -2 4
006
Unit for user-defined readoutUnit for user-defined readout
Unit for user-defined readoutUnit for user-defined readout
Unit for user-defined readout No unit Yes Yes 0 5
007
Big display readoutBig display readout
Big display readoutBig display readout
Big display readout Frequency, Hz Yes Yes 0 5
008
Small display readout 1.1Small display readout 1.1
Small display readout 1.1Small display readout 1.1
Small display readout 1.1 Reference , Unit Yes Yes 0 5
009
Small display readout 1.2Small display readout 1.2
Small display readout 1.2Small display readout 1.2
Small display readout 1.2 Motor current, A Yes Yes 0 5
010
Small display readout 1.3Small display readout 1.3
Small display readout 1.3Small display readout 1.3
Small display readout 1.3 Power, kW Yes Yes 0 5
011
Unit of local referenceUnit of local reference
Unit of local referenceUnit of local reference
Unit of local reference Hz Yes Yes 0 5
012
Hand start on LCPHand start on LCP
Hand start on LCPHand start on LCP
Hand start on LCP Enable Yes Yes 0 5
013
OFF/OFF/
OFF/OFF/
OFF/
STOPSTOP
STOPSTOP
STOP
on LCP on LCP
on LCP on LCP
on LCP Enable Yes Yes 0 5
014
Auto start on LCPAuto start on LCP
Auto start on LCPAuto start on LCP
Auto start on LCP Enable Yes Yes 0 5
015
Reset on LCPReset on LCP
Reset on LCPReset on LCP
Reset on LCP Enable Yes Yes 0 5
016
Lock for data changeLock for data change
Lock for data changeLock for data change
Lock for data change Not locked Yes Yes 0 5
017
Operating state at power-up,Operating state at power-up,
Operating state at power-up,Operating state at power-up,
Operating state at power-up, Auto restart Yes Yes 0 5
local controllocal control
local controllocal control
local control
100
ConfigurationConfiguration
ConfigurationConfiguration
Configuration Open loop No Yes 0 5
101
TT
TT
T
oror
oror
or
que characteristicsque characteristics
que characteristicsque characteristics
que characteristics Automatic Energy Optimisation No Yes 0 5
102
Motor powerMotor power
Motor powerMotor power
Motor power
, P, P
, P, P
, P
M,NM,N
M,NM,N
M,N
Depends on the unit 0.25-300 kW No Yes 1 6
103
Motor voltage, UMotor voltage, U
Motor voltage, UMotor voltage, U
Motor voltage, U
M,NM,N
M,NM,N
M,N
Depends on the unit 200 - 500 V No Yes 0 6
104
Motor frMotor fr
Motor frMotor fr
Motor fr
equencyequency
equencyequency
equency
, f, f
, f, f
, f
M,NM,N
M,NM,N
M,N
50 Hz 24-1000 Hz No Yes 0 6
105
Motor current, IMotor current, I
Motor current, IMotor current, I
Motor current, I
M,NM,N
M,NM,N
M,N
Depends on the unit 0.01 - I
VLT,MAX
No Yes -2 7
106
Rated motor speed, nRated motor speed, n
Rated motor speed, nRated motor speed, n
Rated motor speed, n
M,NM,N
M,NM,N
M,N
Depends on 100-60000 rpm No Yes 0 6
par. 102 Motor power
107
Automatic motor adaptation, AMAAutomatic motor adaptation, AMA
Automatic motor adaptation, AMAAutomatic motor adaptation, AMA
Automatic motor adaptation, AMA Optimisation disable No No 0 5
108
Start voltage of parallel motorsStart voltage of parallel motors
Start voltage of parallel motorsStart voltage of parallel motors
Start voltage of parallel motors Depends on par. 103 0.0 - par. 103 Yes Yes -1 6
109
Resonance dampeningResonance dampening
Resonance dampeningResonance dampening
Resonance dampening 100 % 0 - 500 % Yes Yes 0 6
110
High brake-away torqueHigh brake-away torque
High brake-away torqueHigh brake-away torque
High brake-away torque 0.0 sec. 0.0 - 0.5 sec. Yes Yes -1 5
111
Start delayStart delay
Start delayStart delay
Start delay 0.0 sec. 0.0 - 120.0 sec. Yes Yes -1 6
112
Motor preheaterMotor preheater
Motor preheaterMotor preheater
Motor preheater Disable Yes Yes 0 5
113
Motor preheater DC currentMotor preheater DC current
Motor preheater DC currentMotor preheater DC current
Motor preheater DC current 50 % 0 - 100 % Yes Yes 0 6
114
DC braking currentDC braking current
DC braking currentDC braking current
DC braking current 50 % 0 - 100 % Yes Yes 0 6
115
DC braking timeDC braking time
DC braking timeDC braking time
DC braking time 10.0 sec. 0.0 - 60.0 sec. Yes Yes -1 6
116
DC brake cut-in frequencyDC brake cut-in frequency
DC brake cut-in frequencyDC brake cut-in frequency
DC brake cut-in frequency OFF 0.0-par. 202 Yes Yes -1 6
117
Motor thermal protectionMotor thermal protection
Motor thermal protectionMotor thermal protection
Motor thermal protection ETR trip 1 Yes Yes 0 5

Table of Contents

Other manuals for Danfoss VLT 6000 HVAC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 6000 HVAC and is the answer not in the manual?

Danfoss VLT 6000 HVAC Specifications

General IconGeneral
BrandDanfoss
ModelVLT 6000 HVAC
CategoryDC Drives
LanguageEnglish

Related product manuals