0-37 Display Text 1
Range: Function:
0 N/A* [0 - 0 N/A] In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently, select Display Text 1 in par. 0-20
Display
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
, par. 0-23
Display
Line 2 Large
or par. 0-24
Display Line 3 Large
. Use the
or
buttons on the LCP to change a
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, it can be changed. Use the
or
buttons on the LCP to change a character. A character
can be inserted by placing the cursor between two characters and pressing
or
.
0-38 Display Text 2
Range: Function:
0 N/A* [0 - 0 N/A] In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 2 in par. 0-20
Display
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
, par. 0-23
Display
Line 2 Large
or par. 0-24
Display Line 3 Large
. Use the
or
buttons on the LCP to change a
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
.
0-39 Display Text 3
Range: Function:
0 N/A* [0 - 0 N/A] In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently, select Display Text 3 in par. 0-20
Display
Line 1.1 Small
,par. 0-21
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
, par. 0-23
Display
Line 2 Large
or par. 0-24
Display Line 3 Large
. Use the
or
buttons on the LCP to change a
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
.
0-70 Set Date and Time
Range: Function:
2000-01-01
00:00 –
2099-12-01
23:59 *
[2000-01-01 00:00] Sets the date and time of the internal clock. The format to be used is set in par. 0-71 and 0-72.
NOTE!
This parameter does not display the actual time. This can be read in par. 0-89.
The clock will not begin counting until a setting different from default has been
made.
0-71 Date Format
Option: Function:
[0] * YYYY-MM-DD Sets the date format to be used in the LCP.
[1] DD-MM-YYYY Sets the date format to be used in the LCP.
[2] MM/DD/YYYY Sets the date format to be used in the LCP.
VLT AQUA High Power Instruction Manual
5 How to program the adjustable frequency
drive
MG.20.P3.22 - VLT
®
is a registered Danfoss trademark
5-13