13-01 Start Event
Option: Function:
[47] Up key
[47] Up key The [
] key is pressed.
[48] Down key
[48] Down key The [
] key is pressed.
[50] Comparator 4
[50] Comparator 4 Use the result of
comparator 4.
[51] Comparator 5
[51] Comparator 5 Use the result of
comparator 5.
[60] Logic rule 4
[60] Logic rule 4 Use the result of logic
rule 4.
[61] Logic rule 5
[61] Logic rule 5 Use the result of logic
rule 5.
[94] RS Flipflop 0
[95] RS Flipflop 1
[96] RS Flipflop 2
[97] RS Flipflop 3
[98] RS Flipflop 4
[99] RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
13-02 Stop Event
Select the boolean (TRUE or FALSE) input to activate Smart Logic
Control.
Option: Function:
[0] * False
For descriptions [0]-[61], see
13-01 Start Event Start Event
[1] True
[2] Running
[3] In range
[4] On reference
[5] Torque limit
[6] Current limit
[7] Out of current range
[8] Below I low
[9] Above I high
[10] Out of speed range
[11] Below speed low
[12] Above speed high
[13] Out of feedb. range
[14] Below feedb. low
[15] Above feedb. high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
13-02 Stop Event
Select the boolean (TRUE or FALSE) input to activate Smart Logic
Control.
Option: Function:
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[37] Digital input DI32
[38] Digital input DI33
[39] Start command
[40] Drive stopped
[41] Reset Trip
[42] Auto-reset Trip
[43] Ok key
[44] Reset key
[45] Left key
[46] Right key
[47] Up key
[48] Down key
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[70] SL Time-out 3 Smart Logic
Controller timer 3 is timed out.
[71] SL Time-out 4
[71] SL Time-out 4 Smart Logic
Controller timer 4 is timed out.
[72] SL Time-out 5
[72] SL Time-out 5 Smart Logic
Controller timer 5 is timed out.
[73] SL Time-out 6
[73] SL- Time-out 6 Smart Logic
Controller timer 6 is timed out.
[74] SL Time-out 7
[74] SL Time-out 7 Smart Logic
Controller timer 7 is timed out.
[75] Start command given
[76] Digital input x30/2
[77] Digital input x30/3
[78] Digital input x30/4
[79] Digital input x46/1
[80] Digital input x46/3
[81] Digital input x46/5
[82] Digital input x46/7
[83] Digital input x46/9
[84] Digital input x46/11
[85] Digital input x46/13
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®