Q3-3 Closed Loop Settings
Q3-30 Single Zone Int. Set Point Q3-31 Single Zone Ext. Set Point Q3-32 Multi Zone / Adv
Par. 1-00 
Configuration Mode
Par. 1-00 
Configuration Mode
Par. 1-00 
Configuration Mode
Par. 20-12 
Reference/Feedback Unit
Par. 20-12 
Reference/Feedback Unit
Par. 3-15 
Reference 1 Source
Par. 20-13 
Minimum Reference/Feedb.
Par. 20-13 
Minimum Reference/Feedb.
Par. 3-16 
Reference 2 Source
Par. 20-14 
Maximum Reference/Feedb.
Par. 20-14 
Maximum Reference/Feedb.
Par. 20-00 
Feedback 1 Source
Par. 6-22 
Terminal 54 Low Current
Par. 6-10 
Terminal 53 Low Voltage
Par. 20-01 
Feedback 1 Conversion
Par. 6-24 
Terminal 54 Low Ref./Feedb. Value
Par. 6-11 
Terminal 53 High Voltage
Par. 20-02 
Feedback 1 Source Unit
Par. 6-25 
Terminal 54 High Ref./Feedb. Value
Par. 6-12 
Terminal 53 Low Current
Par. 20-03 
Feedback 2 Source
Par. 6-26 
Terminal 54 Filter Time Constant
Par. 6-13 
Terminal 53 High Current
Par. 20-04 
Feedback 2 Conversion
Par. 6-27 
Terminal 54 Live Zero
Par. 6-14 
Terminal 53 Low Ref./Feedb. Value
Par. 20-05 
Feedback 2 Source Unit
Par. 6-00 
Live Zero Timeout Time
Par. 6-15 
Terminal 53 High Ref./Feedb. Value
Par. 20-06 
Feedback 3 Source
Par. 6-01 
Live Zero Timeout Function
Par. 6-22 
Terminal 54 Low Current
Par. 20-07 
Feedback 3 Conversion
Par. 20-21 
Setpoint 1
Par. 6-24 
Terminal 54 Low Ref./Feedb. Value
Par. 20-08 
Feedback 3 Source Unit
Par. 20-81 
PID Normal/ Inverse Control
Par. 6-25 
Terminal 54 High Ref./Feedb. Value
Par. 20-12 
Reference/Feedback Unit
Par. 20-82 
PID Start Speed [RPM]
Par. 6-26 
Terminal 54 Filter Time Constant
Par. 20-13 
Minimum Reference/Feedb.
Par. 20-83 
PID Start Speed [Hz]
Par. 6-27 
Terminal 54 Live Zero
Par. 20-14 
Maximum Reference/Feedb.
Par. 20-93 
PID Proportional Gain
Par. 6-00 
Live Zero Timeout Time
Par. 6-10 
Terminal 53 Low Voltage
Par. 20-94 
PID Integral Time
Par. 6-01 
Live Zero Timeout Function
Par. 6-11 
Terminal 53 High Voltage
Par. 20-70 
Closed Loop Type
Par. 20-81 
PID Normal/ Inverse Control
Par. 6-12 
Terminal 53 Low Current
Par. 20-71 
PID Performance
Par. 20-82 
PID Start Speed [RPM]
Par. 6-13 
Terminal 53 High Current
Par. 20-72 
PID Output Change
Par. 20-83 
PID Start Speed [Hz]
Par. 6-14 
Terminal 53 Low Ref./Feedb. Value
Par. 20-73 
Minimum Feedback Level
Par. 20-93 
PID Proportional Gain
Par. 6-15 
Terminal 53 High Ref./Feedb. Value
Par. 20-74 
Maximum Feedback Level
Par. 20-94 
PID Integral Time
Par. 6-16 
Terminal 53 Filter Time Constant
Par. 20-79 
PID Autotuning
Par. 20-70 
Closed Loop Type
Par. 6-17 
Terminal 53 Live Zero
Par. 20-71 
PID Performance
Par. 6-20 
Terminal 54 Low Voltage
Par. 20-72 
PID Output Change
Par. 6-21 
Terminal 54 High Voltage
Par. 20-73 
Minimum Feedback Level
Par. 6-22 
Terminal 54 Low Current
Par. 20-74 
Maximum Feedback Level
Par. 6-23 
Terminal 54 High Current
Par. 20-79 
PID Autotuning
Par. 6-24 
Terminal 54 Low Ref./Feedb. Value
Par. 6-25 
Terminal 54 High Ref./Feedb. Value
Par. 6-26 
Terminal 54 Filter Time Constant
Par. 6-27 
Terminal 54 Live Zero
Par. 6-00 
Live Zero Timeout Time
Par. 6-01 
Live Zero Timeout Function
Par. 4-56 
Warning Feedback Low
Par. 4-57 
Warning Feedback High
Par. 20-20 
Feedback Function
Par. 20-21 
Setpoint 1
Par. 20-22 
Setpoint 2
Par. 20-81 
PID Normal/ Inverse Control
Par. 20-82 
PID Start Speed [RPM]
Par. 20-83 
PID Start Speed [Hz]
Par. 20-93 
PID Proportional Gain
Par. 20-94 
PID Integral Time
Par. 20-70 
Closed Loop Type
Par. 20-71 
PID Performance
Par. 20-72 
PID Output Change
Par. 20-73 
Minimum Feedback Level
Par. 20-74 
Maximum Feedback Level
Par. 20-79 
PID Autotuning
VLT HVAC Low Harmonic Drive Operating In-
structions 6 How to Programme the Low Harmonic Drive
MG.16.A1.02 - VLT
®
 is a registered Danfoss trademark 93