30-22 Locked Rotor Protection
Default value: [0] Off
Parameter type: Option
2-setup: All setups
Conversion index: -
Data type: u_int8
Change during operation: True
Set the locked rotor detection for PM motors.
Table 467: Option:
[0]
Off
[1]
On
30-23 Locked Rotor Detection Time [s]
Default value: 0.10 s
Parameter type: Range
2-setup: All setups
Conversion index: -2
Data type: u_int8
Change during operation: True
Set the locked rotor detection time in seconds for PM motors.
Table 468: Range:
Min: 0.05
Max: 1.00
Default value: 0.10