EasyManuals Logo
Home>Danfoss>DC Drives>VLT Flow Drive FC 111

Danfoss VLT Flow Drive FC 111 User Manual

Danfoss VLT Flow Drive FC 111
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
1.
2.
3.
Select the parameter and press [OK].
Press []/[] to scroll through the indexed values.
To change the parameter value, select the indexed value and press [OK].
Change the value by pressing []/[].
Press [OK] or [Cancel] to accept or abort the new setting.
Press [Back] to leave the parameter.
3.5 Initialization to Default Settings
There are 2 ways to initialize the drive to the default settings.
Recommended initialization
Two-finger initialization
Initialization of parameters is confirmed by alarm 80, Drive initialised in the display after the power cycle.
3.5.1 Recommended Initialization
Procedure
Select parameter 14-22 Operation Mode.
Press [OK].
Select [2] Initialisation and press [OK].
Power off the drive and wait until the display turns off.
Reconnect the mains supply. The drive is now reset, except for the following parameters.
Parameter 1-06 Clockwise Direction
Parameter 8-30 Protocol
Parameter 8-31 Address
Parameter 8-32 Baud Rate
Parameter 8-33 Parity / Stop Bits
Parameter 8-35 Minimum Response Delay
Parameter 8-36 Maximum Response Delay
Parameter 8-37 Maximum Inter-char delay
Parameter 8-70 BACnet Device Instance
Parameter 8-72 MS/TP Max Masters
Parameter 8-73 MS/TP Max Info Frames
Parameter 8-74 "I am" Service
Parameter 8-75 Intialisation Password
Parameter 15-00 Operating hours to parameter 15-05 Over Volt's
Parameter 15-03 Power Up's
Parameter 15-04 Over Temp's
Parameter 15-05 Over Volt's
Parameter 15-30 Alarm Log: Error Code
Parameter group 15-4* Drive identification
Parameter 18-10 FireMode Log:Event
3.5.2 Two-finger Initialization
Procedure
Power off the drive.
Press [OK] and [Menu].
Power up the drive while still pressing the keys for 10 s.
AU363928304090en-000101 / 130R0982 | 27Danfoss A/S © 2021.07
Programming
VLT® Flow Drive FC 111
Programming Guide

Table of Contents

Other manuals for Danfoss VLT Flow Drive FC 111

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Flow Drive FC 111 and is the answer not in the manual?

Danfoss VLT Flow Drive FC 111 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Flow Drive FC 111
CategoryDC Drives
LanguageEnglish

Related product manuals