Parameter 1-10 Motor Construction
[0] Asynchron
[1] PM, non salient SPM
[3] PM, salient IPM
Parameter 2-07 Parking Time
x
x
Parameter 2-10 Brake Function
x
x
x
Parameter 2-16 AC brake Max. Current
x
Parameter 2-17 Over-voltage Control
x
x
x
Parameter 4-10 Motor Speed Direction
x
x
x
Parameter 4-14 Motor Speed High Limit [Hz]
x
x
x
Parameter 4-18 Current Limit
x
x
x
Parameter 4-19 Max Output Frequency
x
x
x
Parameter 4-58 Missing Motor Phase Function
x
x
x
Parameter 14-01 Switching Frequency
x
x
x
Parameter 14-03 Overmodulation
x
x
x
Parameter 14-07 Dead Time Compensation Level
x
x
x
Parameter 14-08 Damping Gain Factor
x
x
x
Parameter 14-09 Dead Time Bias Current Level
x
x
x
Parameter 14-10 Mains Failure
x
x
x
Parameter 14-11 Mains Fault Voltage Level
x
x
x
Parameter 14-12 Function at Mains Imbalance
x
x
x
Parameter 14-27 Action At Inverter Fault
x
x
x
Parameter 14-40 VT Level
x
x
x
Parameter 14-41 AEO Minimum Magnetisation
x
x
x
Parameter 14-44 d-axis current optimization for IPM
x
Parameter 14-50 RFI Filter
x
Parameter 14-51 DC-Link Voltage Compensation
x
x
x
Parameter 14-55 Output Filter
x
x
x
Parameter 14-64 Dead Time Compensation Zero Current Level
x
x
x
Parameter 14-65 Speed Derate Dead Time Compensation
x
x
x
Parameter 30-22 Locked Rotor Protection
x
x
Parameter 30-23 Locked Rotor Detection Time [s]
x
x
1-14 to 1-17 VVC
+
PM
The default control parameters for VVC+ PM motor control core are optimized for applications and inertia load in the range of
50>Jl/Jm>5. Jl is load inertia from the application and Jm is machine inertia.
For low inertia applications (Jl/Jm<5), it is recommended that parameter 1-17 Voltage filter time const. is increased with a factor of 5–
10. Sometimes, parameter 14-08 Damping Gain Factor should also be reduced to improve performance and stability.
For high-inertia applications (Jl/Jm>50), increase parameter 1-15 Low Speed Filter Time Const. and parameter 1-16 High Speed Filter
Time Const. to improve performance and stability.
AU363928304090en-000101 / 130R098244 | Danfoss A/S © 2021.07
Parameters
VLT® Flow Drive FC 111
Programming Guide

Table of Contents

Other manuals for Danfoss VLT Flow Drive FC 111

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Flow Drive FC 111 and is the answer not in the manual?

Danfoss VLT Flow Drive FC 111 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Flow Drive FC 111
CategoryDC Drives
LanguageEnglish

Related product manuals