8.1.2. Line Supply 3 x 380-480 V AC
Normal overload 110% for 1 minute
Adjustable frequency drive
Typical Shaft Output [kW]
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P4K0
4
P5K5
5.5
P7K5
7.5
Typical Shaft Output [HP] at 460 V 1.5 2.0 2.9 4.0 5.3 7.5 10
IP 20 A2 A2 A2 A2 A2 A3 A3
IP 21
IP 55 A5 A5 A5 A5 A5 A5 A5
IP 66
A5 A5 A5 A5 A5 A5 A5
Output current
Continuous
(3 x 380-440 V) [A]
3 4.1 5.6 7.2 10 13 16
Intermittent
(3 x 380-440 V) [A]
3.3 4.5 6.2 7.9 11 14.3 17.6
Continuous
(3 x 440-480 V) [A]
2.73.44.86.38.2
11 14.5
Intermittent
(3 x 440-480 V) [A]
3.0 3.7 5.3 6.9 9.0 12.1 15.4
Continuous kVA
(400 V AC) [kVA]
2.12.83.95.06.9
9.0 11.0
Continuous kVA
(460 V AC) [kVA]
2.4 2.7 3.8 5.0 6.5 8.8 11.6
Max. cable size:
(line, motor, brake)
[[mm
2
/
AWG]
2)
4/
10
Max. input current
Continuous
(3 x 380-440 V) [A]
2.7 3.7 5.0 6.5 9.0 11.7 14.4
Intermittent
(3 x 380-440 V) [A]
3.0 4.1 5.5 7.2 9.9
12.9 15.8
Continuous
(3 x 440-480 V) [A]
2.7 3.1 4.3 5.7 7.4 9.9 13.0
Intermittent
(3 x 440-480 V) [A]
3.0 3.4 4.7 6.3 8.1
10.9 14.3
Max. pre-fuses
1)
[A]
10 10 20 20 20 32 32
Environment
Estimated power loss
at rated max. load [W]
4)
58 62 88 116 124 187 255
Weight enclosure IP 20 [kg] 4.8 4.9 4.9 4.9 4.9
6.6 6.6
Weight enclosure IP 21 [kg]
Weight enclosure IP 55 [kg] 13.5 13.5 13.5 13.5 13.5
14.2 14.2
Weight enclosure IP 66 [kg] 13.5 13.5 13.5 13.5 13.5 14.2 14.2
Efficiency
3)
0.96 0.97 0.97 0.97 0.97 0.97 0.97