The MCT 10 Set-up Software Modules
The following modules are included in the software package:
MCT 10 Set-up Software
Setting parameters
Copy to and from adjustable frequency drives
Documentation and print-out of parameter settings incl. diagrams
Ext. User Interface
Preventive Maintenance Schedule
Clock settings
Timed Action Programming
Smart Logic Controller Set-up
Ordering number:
Please order the CD containing the MCT 10 Set-up software using code number 130B1000.
MCT 10 can also be downloaded from the Danfoss website:
www.danfoss.com - Business Area:
Motion Controls
.
5.1.7. Tips and tricks
* For the majority of HVAC applications, the Quick Menu, Quick Set-up and Func-
tion Set-up provide the simplest and quickest access to all the most commonly
required parameters.
* Whenever possible, perform an AMA to ensure the best shaft performance
* Display contrast can be adjusted by pressing [Status] and [ ] for a darker display
or by pressing [Status] and [ ] for a brighter display.
* Under [Quick Menu] and [Changes Made], all the parameters that have been
changed from the factory settings are displayed.
* Press and hold the [Main Menu] key for 3 seconds to access to any parameter.
* For service purposes, it is recommended to copy all parameters to the LCP; see
par 0-50 for further information.
Table 5.1: Tips and tricks
5.1.8. Quick Transfer of Parameter Settings when using GLCP
Once the set-up of an adjustable frequency drive is complete, it is recommended to store (backup)
the parameter settings in the GLCP or on a PC via MCT 10 Set-up software tool.
NOTE
Stop the motor before performing any of these operations.
5. How to operate the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
60
MG.11.A4.22 - VLT
®
is a registered Danfoss trademark
5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT HVAC Drive and is the answer not in the manual?

Danfoss VLT HVAC Drive Specifications

General IconGeneral
TypeVLT HVAC Drive
STO (Safe Torque Off)Yes
EnclosureIP20
Output Frequency0-500 Hz
Brake ChopperBuilt-in (depending on frame size)
EMC FilterBuilt-in (depending on frame size)
CommunicationEthernet
Power Range0.37 kW to 630 kW
Input Voltage200-240V, 380-480V, 525-600V
Protection FeaturesOverload, Overvoltage, Undervoltage, Short Circuit, Ground Fault
Ambient Temperature-10°C to +50°C (with derating above +40°C)
Storage Temperature-25°C to +70°C
Relative Humidity5-95% (non-condensing)
Cooling MethodAir-cooled