EasyManuals Logo

Datalogic CBX800 User Manual

Datalogic CBX800
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
CBX800 INSTALLATION MANUAL
8
NOTE
Vdc is electrically connected to +V, just as GND is electrically connected to -V. This is useful
for supplying external trigger, inputs and outputs from the CBX800 power source, however
+V and -V signals should not be used as power supply inputs to the CBX800.
The power supply must be between 10 and 30 Vdc only.
SYSTEM WIRING
The connection and wiring procedure for CBX800 is described as follows:
1) Open the CBX800 by unscrewing the four cover screws.
2) Verify that the CBX800 power switch is off (see Figure 4).
3) Unscrew the compression connectors and pass all the system cables through them into the CBX800 housing.
4) To connect the power and input/output signals:
Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm.
Using a device such as a screwdriver, push down on the lever directly next to the clamp (see Figure 5).
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
5) Tighten the compression connector nuts so that the internal glands seal around the cables.
Figure 5 - System Cable Connections
Flexible stranded wire should be used and must meet the following specifications.
All positions: 24 - 16 AWG 0.2 - 1.5 mm²
The CBX800 spring clamp connector pinouts are indicated in the Pinout table.
Refer to the reading device Installation Manual for signal details.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic CBX800 and is the answer not in the manual?

Datalogic CBX800 Specifications

General IconGeneral
Product colorBlack, Blue, Grey
LED indicatorsYes
Housing material-
Protection featuresShock resistant, Vibration proof
International Protection (IP) codeIP65
Input voltage10/30 V
Power source typeDC
Power consumption (typical)2.5 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)0 - 90 %
TypeBarcode module bar barcode readers
Scanner type1D/2D
Connectivity technologyWired
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth137 mm
Width128 mm
Height62 mm
Weight360 g