DRAGON™ D131/M131
166
5.14.2 Copy Dragon™ M131 Series
Procedure
:
Using the slave reader and its OM-30X0 cradle, follow the initialization
procedure in chapter 4 of this manual or from the Quick Reference Manual.
With the master Dragon™ M131 (correctly configured reader), read the Copy
Configuration barcode below. Then place it onto an OM-30X0 cradle within 10
seconds. The reader will beep indicating the configuration has been copied.
The configuration will be simultaneously sent over the RS232 interface of the
OM-30X0. If this causes undesired effects disconnect the RS232 cable between
the PC and OM-30X0 during this process.
Copy Configuration
Ì$+ZZ0$-*Î
With the slave Dragon™ M131, read the Get Configuration barcode below.
Then place it onto the same OM-30X0 cradle used in the step above. The slave
reader's address will not be changed.
Get Configuration
Ì$+ZZ2$-4Î
The configuration will be copied from the master to the slave Dragon™ M131. The
slave Dragon™ M131 signals the end of the procedure with a series of beeps. It is
now ready to be used with its own OM-30X0 cradle.
Repeat the procedure above to configure other slave readers. The
OM-30X0 can continue to configure slave readers until it receives another
command or data.