DRAGON™ D131/M131
26
4.3 DRAGON™ D131 SETUP
1.
Read the restore default parameters code below.
Restore Dragon™ D131 Default
Ì$+$*oÎ
After reading the above code, go to par. 4.8 Interface Selection.
4.4 DRAGON™ M131/OM-30X0 POINT-TO-POINT SETUP
A rapid configuration procedure has been devised for point-to-point applications
where a single
reader is associated exclusively with its own OM-30x0 base station
and where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the OM-30x0 base station
package can be used to bind the Dragon™ M131 reader to the base station with the
address coded on the label. The address is also written numerically on the label to be
easily recognized. Valid addresses are in the range from 0000 to 1999. Make sure
that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
1.
Apply the bind-address label onto the OM-30x0 base station as indicated in
the OM-30x0 Quick Reference Manual.
2.
When the OM-30X0 cradle is connected and powered, read the Bind-
Address label to pair the Dragon™ M131 to the OM-30X0 cradle.
The green LED on the Dragon™ M131 will blink: the reader is ready to be
positioned onto the cradle.
3.
Firmly position the reader onto the cradle within 10 seconds, a beep will be
emitted, signaling that the OM-30X0 cradle has been paired to the Dragon™
M131, and the green LED on the reader will go off.
If it ever becomes necessary to change the reader,
just read the bind-address label applied to the
cradle and position the new reader onto the cradle.
Do not use multiple guns with this configuration
method.
4.
Configure the OM-30X0 cradle, refer to the “OM-30X0 Quick Reference”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
Green LED