RSS Limited
Product Reference Guide
5-25
RSS Limited — continued
RSS Limited UCC/EAN 128 Emulation
When enabled, RSS Limited bar codes will be translated to the UCC/EAN 128 label data for-
mat.
Minimum Reads
This feature specifies the minimum number of consecutive times an RSS Limited label must be
decoded before it is accepted as a good read.
START / END
PROGRAMMING BAR CODES
Disable RSS Limited UCC/EAN 128 Emulation
DEFAULT
Enable RSS Limited UCC/EAN 128 Emulation
START / END
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads