62
QuickScan 6000/6000 Plus
Code 128 Options
AIM Symbology ID Prefix
The Automatic Identification Manufacturers, Inc. of the United States (AIM
USA) have standardized the reporting of data sources from bar code
reading devices. Sending the AIM symbology prefix identifies the symbol-
ogy to the host terminal, allowing it to specifically differentiate between
UCC-128 (Code 128 with Function Character 1 in the first position) and
standard Code 128 symbols. When this feature is disabled, the host
cannot differentiate between these symbols.
Scan the labels below to enable or disable the sending of an AIM symbol-
ogy ID prefix.
SET ----------------------------------------------
ENABLE -----------------------------
DISABLE -----------------------------
END ----------------------------------------------
AIM S
YMBOLOGY
ID P
REFIX