5.1.2 Digital / IO-Link ,2EV or 3EV module (Ref. 7162002)
Terminal
number
Description
Digital
Digital
Pigging Mode
Pigging Mode
With M12
connector
1
+24V
V+
V+
V+ & V+ Sensor 3
V+ & V+ Sensor 3
Pin 1 (brown)
2
GND
V-
V-
V- & V- Sensor 3
V- & V- Sensor 3
Pin 3 (blue)
3
PLC in / com
Status OK
IO-Link
Status
IO-Link
Pin 4 (black)
4
PLC in
De-energized
n.a.
Sensor 1
n.a.
Pin 5 (grey)
5
PLC in
Main Energized
n.a.
Sensor 2
n.a.
Pin 6 (pink)
6
PLC in
Upper seat activated
n.a.
Sensor 3
n.a.
7
PLC in
Lower seat activated
n.a.
n.a.
n.a.
8
PLC out
Activating SV1
n.a.
Activating SV1
n.a.
Pin 2 (white)
9
PLC out
Activating SV2
n.a.
Activating SV2
n.a.
Pin 7 (violet)
10
PLC out
Activating SV3
n.a.
Signal sensor 3
Signal sensor 3
Pin 8 (orange)
21
+24V
Ext. Sensor
V+ EXT
V+ EXT
V+ EXT
V+ EXT
22
GND
Ext. Sensor
V- EXT
V- EXT
V- EXT
V- EXT
23
PLC in Ext.
Sensor
Signal EXT
Signal EXT
Signal EXT
Signal EXT
31
+24V
Aux. Sensor
V+ AUX
V+ AUX
V+ AUX
V+ AUX
32
PLC in
Aux. Sensor
Signal AUX
Signal AUX
Signal AUX
Signal AUX
33
GND
Aux. Sensor
V- AUX
V- AUX
V- AUX
V- AUX