MAINTENANCE NOTICE
NM-275 index 09 Page 20/50 September 2021
7.3 2EV Sorio
®
unit
7.3.1 On VEOX actuator
• Connect the quick connector square 11a to the
quick connector square 11b with a pneumatic
tube 4/6.
• Connect the quick connector square 11 to the
smooth square with a pneumatic tube 4/6.
• Wire the electric cables depending on the type
of unit and following the connection diagrams
provided in this manual.
• Restore pressure on channel P using the right
quick connector 7.
7.3.2 On VDCI MC actuator
• Connect the quick connector square 11a to the
quick connector square 11b with a pneumatic
tube 4/6.
• Connect the quick connector square 11 to the
smooth square with a pneumatic tube 4/6.
• Wire the electric cables depending on the type
of unit and following the connection diagrams
provided in this manual.
• Restore pressure on channel P using the right
quick connector 7.
Smooth
square
11
11a
7
11b
11
7
11a
Smooth
square